• 330103-00-03-10-02-CN  Eddy current probe  It has non-contact measurement, high precision and high resolution
  • 330103-00-03-10-02-CN  Eddy current probe  It has non-contact measurement, high precision and high resolution

330103-00-03-10-02-CN Eddy current probe It has non-contact measurement, high precision and high resolution

No.330103-00-03-10-02-CN
 ● Manufacturer: Bentley Nevada

● Product Number :330103-00-03-10-02-CN

● Product type: Close probe

● Made in the USA

● No thread length option :00

● Total case length option :03 = 30

● Total length options :10 = 1.0 m (3.3 ft)
  • 330103-00-03-10-02-CN  Eddy current probe  It has non-contact measurement, high precision and high resolution
Desciption
 ● Manufacturer: Bentley Nevada

● Product Number :330103-00-03-10-02-CN

● Product type: Close probe

● Made in the USA

● No thread length option :00

● Total case length option :03 = 30

● Total length options :10 = 1.0 m (3.3 ft)
330103-00-03-10-02-CN Eddy current probe is a measurement tool based on eddy current effect, usually composed of coils, frame cables, joints and other parts. When an alternating current is passed through the coil, an alternating magnetic field is generated, which generates an induced current on the metal surface under test, that is, an eddy current. The size and phase of the eddy current are related to the surface characteristics, distance, conductivity and permeability of the measured metal. The 330103-00-03-10-02-CN eddy current probe uses this principle to indirectly measure the surface characteristics, displacement, vibration and other parameters of the measured metal by measuring the change of eddy current. The signal output by the probe is usually a voltage or current signal, which can be processed and analyzed by the signal processor to obtain the physical quantity to be measured. When using the eddy current probe, it is necessary to pay attention to the following points: Select the appropriate probe model and specification, and choose according to the material, shape, size and other factors of the metal to be measured. 

When installing the probe, ensure that the distance and position relationship between the probe and the metal surface to be measured are correct to avoid measurement errors. In the measurement process, it is necessary to avoid the influence of external interference and noise to ensure the accuracy and stability of the measurement results. 330103-00-03-10-02-CN Eddy current probes are widely used in various mechanical, aerospace, energy and other fields, such as bearing monitoring, crack detection, displacement measurement, etc. It has the advantages of non-contact measurement, high precision, high resolution and so on, and plays an important role in industrial automation and quality control.