369-LO-0-M-F-E-0-0  Data acquisition Intelligent telemetry terminal RTU-- heating pioneer army, integrated remote pressure gauge

The pressure difference in the heating system mainly has the following: the pressure difference between the inlet and outlet of the circulating pump, the pressure difference between the inlet and outlet of the boiler, the water pressure difference between the supply and return of the heating external network, the pressure difference between the inlet and outlet of the decondaminator, and the pressure difference between the inlet and outlet of the hot user.
Nov 29th,2023 161 Views
Usually, the pressure in the heating system is not the same in the normal operation of the system, so it is necessary to monitor the pressure everywhere. In heating engineering, pressure difference and resistance in most cases are synonymous, fluid flow in a certain pressure situation, flow through a hydraulic element, a section of pipe, the flow is constant, the pressure is reduced, called pressure loss, this pressure loss can be measured using pressure meters, called pressure difference, referred to as pressure difference.

The pressure difference in the heating system mainly has the following: the pressure difference between the inlet and outlet of the circulating pump, the pressure difference between the inlet and outlet of the boiler, the water pressure difference between the supply and return of the heating external network, the pressure difference between the inlet and outlet of the decondaminator, and the pressure difference between the inlet and outlet of the hot user. In other words, these places should be equipped with pressure gauges to monitor the heating situation. When the water pressure difference between the supply and return of the heat user is insufficient, the flow rate is certainly insufficient, and the heating effect is certainly poor. The heating company can monitor the pressure to see if the heating is working properly in real time. The integrated remote pressure gauge developed by Tangshan Landi can be applied to heating pressure monitoring.
Integrated remote pressure gauge is a high-performance iot pressure gauge developed for market demand, integrating signal acquisition, data storage and wireless data communication. It adopts ultra-low power consumption technology and uses disposable lithium battery power supply. Without the need of power supply, you can directly monitor pressure data in real time, collect digital signals, analog signals, level signals, dry contacts, pulse signals, etc., and have the function of automatic detection and real-time alarm of upper and lower limits.

1. Application field

Urban water supply pipeline pressure and flow monitoring; City gas pipeline pressure and flow monitoring; Pipeline leakage monitoring system; Tank, tank pressure, liquid level monitoring; Oil well pressure monitoring; Fire pipe pressure monitoring
Second, product features:

Low power design, energy saving and environmental protection, high channel data transmission security, 4G, 5G, NB-IoT, LoRa optional, IP68, waterproof, explosion-proof.
Third, product function

01. Monitoring function

Monitor the pipeline pressure data, and reserve RS485 interface, digital interface, can collect other instrument signals.

02. Transmission function

Embedded 4G, NB-lot, LoRa modules, to achieve acquisition, storage, wireless transmission in one;

03. Data interface

Analog signal input: 2 analog signal input, can be connected to water level, temperature, water quality and other transmitters output current or voltage signals;

Pulse volume signal input: 3 pulse signal input, can be connected to water meter, rainfall and other pulse sensors; For the water meter can achieve forward and reverse metering;

Digital signal input: 1 RS485 interface, can be connected to the user intelligent instrument;

04. Communication protocol

Standard MODBUS-RTU protocol, support configuration software, such as: Asia control, power control, JEChong, Purple gold Bridge and other configuration software. Lundy 68 protocol: Custom;

05. Meter reading function

Embedded a variety of manufacturer instrument protocols, unified data active reporting format, reduce the difficulty of PC development;

06. Boost voltage function

The device has an internal voltage boost function, which can provide 5VDC, 12VDC, 24VDC power supply for other equipment on site.

07. Display function

LCD display field monitoring data and working parameters, such as: pressure, flow, battery voltage, time, working status, etc.

08. Data storage function

The collected data is stored periodically, and the storage period can be set arbitrarily;

4 BYTES flash storage space, the number of records stored is not less than 100,000;

09. Data recruitment function

If the device fails to report this time due to other reasons such as the mobile network, the collected data will be automatically saved and reported to the monitoring center together with the next report.

10. Device alarm function

Monitoring pressure data limit alarm;

Equipment anti-demolition, anti-theft alarm;

Low battery voltage alarm to remind users to replace the battery.